Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
Physiol Rep ; 11(4): e15614, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36823958

RESUMO

We determined the effect of exercise-induced bronchoconstriction (EIB) on the shape of the maximal expiratory flow-volume (MEFV) curve in asthmatic adults. The slope-ratio index (SR) was used to quantitate the shape of the MEFV curve. We hypothesized that EIB would be accompanied by increases in SR and thus increased curvilinearity of the MEFV curve. Adult asthmatic ( n  = 10) and non-asthmatic control subjects ( n  = 9) cycled for 6-8 min at 85% of peak power. Following exercise, subjects remained on the ergometer and performed a maximal forced exhalation every 2 min for a total 20 min. In each MEFV curve, the slope-ratio index (SR) was calculated in 1% volume increments beginning at peak expiratory flow (PEF) and ending at 20% of forced vital capacity (FVC). Baseline spirometry was lower in asthmatics compared to control subjects (FEV1 % predicted, 89.1 ± 14.3 vs. 96.5 ± 12.2% [SD] in asthma vs. control; p  < 0.05). In asthmatic subjects, post-exercise FEV1 decreased by 29.9 ± 13.2% from baseline (3.48 ± 0.74 and 2.24 ± 0.59 [SD] L for baseline and post-exercise nadir; p  < 0.001). At baseline and at all timepoints after exercise, average SR between 80 and 20% of FVC was larger in asthmatic than control subjects (1.48 ± 0.02 vs. 1.23 ± 0.02 [SD] for asthma vs. control; p < 0.005). This averaged SR did not change after exercise in either subject group. In contrast, post-exercise SR between PEF and 75% of FVC was increased from baseline in subjects with asthma, suggesting that airway caliber heterogeneity increases with EIB. These findings suggest that the SR-index might provide useful information on the physiology of acute airway narrowing that complements traditional spirometric measures.


Assuntos
Asma Induzida por Exercício , Curvas de Fluxo-Volume Expiratório Máximo , Adulto , Humanos , Asma/etiologia , Asma/fisiopatologia , Broncoconstrição/fisiologia , Exercício Físico/efeitos adversos , Exercício Físico/fisiologia , Expiração , Volume Expiratório Forçado , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Asma Induzida por Exercício/fisiopatologia
2.
BMC Pulm Med ; 19(1): 208, 2019 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-31711456

RESUMO

BACKGROUND: The expiratory time constant (RCEXP), which is defined as the product of airway resistance and lung compliance, enable us to assess the mechanical properties of the respiratory system in mechanically ventilated patients. Although RCEXP could also be applied to spontaneously breathing patients, little is known about RCEXP calculated from the maximal expiratory flow-volume (MEFV) curve. The aim of our study was to determine the reference value for RCEXP, as well as to investigate the association between RCEXP and other respiratory function parameters, including the forced expiratory volume in 1 s (FEV1)/ forced vital capacity (FVC) ratio, maximal mid-expiratory flow rate (MMF), maximal expiratory flow at 50 and 25% of FVC (MEF50 and MEF25, respectively), ratio of MEF50 to MEF25 (MEF50/MEF25). METHODS: Spirometric parameters were extracted from the records of patients aged 15 years or older who underwent pulmonary function testing as a routine preoperative examination before non-cardiac surgery at the University of Tokyo Hospital. RCEXP was calculated in each patient from the slope of the descending limb of the MEFV curve using two points corresponding to MEF50 and MEF25. Airway obstruction was defined as an FEV1/FVC and FEV1 below the statistically lower limit of normal. RESULTS: We retrospectively analyzed 777 spirometry records, and 62 patients were deemed to have airway obstruction according to Japanese spirometric reference values. The cut-off value for RCEXP was 0.601 s with an area under the receiver operating characteristic curve of 0.934 (95% confidence interval = 0.898-0.970). RCEXP was strongly associated with FEV1/FVC, and was moderately associated with MMF and MEF50. However, RCEXP was less associated with MEF25 and MEF50/MEF25. CONCLUSIONS: Our findings suggest that an RCEXP of longer than approximately 0.6 s can be linked to the presence of airway obstruction. Application of the concept of RCEXP to spontaneously breathing subjects was feasible, using our simple calculation method.


Assuntos
Obstrução das Vias Respiratórias/fisiopatologia , Expiração/fisiologia , Pulmão/fisiopatologia , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Adolescente , Obstrução das Vias Respiratórias/diagnóstico , Estudos de Viabilidade , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Período Pré-Operatório , Curva ROC , Valores de Referência , Estudos Retrospectivos , Espirometria , Procedimentos Cirúrgicos Operatórios
3.
BMC Pulm Med ; 16: 18, 2016 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-26801632

RESUMO

BACKGROUND: Conventional spirometric parameters have shown poor correlation with symptoms and health status of chronic obstructive pulmonary disease (COPD). While it is well-known that the pattern of the expiratory flow-volume curve (EFVC) represents ventilatory dysfunction, little attempts have been made to derive quantitative parameters by analyzing the curve. In this study, we aimed to derive useful parameters from EFVC via graphic analysis and tried to validate them in patients with COPD. METHODS: Using Graphical Analysis 3.4 Vernier Software, we derived from the EFVC such parameters as area of obstruction (Ao), area of triangle (AT), area of rectangle (AR) and ratio of volume at 75 and 25% peak expiratory flow (PEF) (0.25/0.75 V). For validation, we reviewed clinical and spirometric data of 61 COPD patients from Seoul National University Airway Registry (SNUAR) and Korean obstructive Lung Disease (KOLD) cohorts. RESULTS: Of all parameters, only RV/TLC significantly correlated with scores from St. George's Respiratory Questionnaire (SGRQ) (r = 0.447, p = 0.037). Six-minute walking distance (6MWD) highly correlated with Ao/AR (r = -0.618, p = 0.005) and Ao/PEF (r = -0.581, p = 0.009) whereas neither FEV1 nor FEV1/FVC had significant correlation with 6MWD. CONCLUSIONS: Ao/AR and Ao/PEF are promising parameters which correlate well with the exercising capacity of COPD patients.


Assuntos
Nível de Saúde , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Idoso , Tolerância ao Exercício , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Espirometria , Capacidade Vital
4.
Respir Physiol Neurobiol ; 220: 46-53, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26388199

RESUMO

Differences in the absolute flow and volume of maximal expiratory flow-volume (MEFV) curves have been studied extensively in health and disease. However, the shapes of MEFV curves have received less attention. We questioned if the MEFV curve shape was associated with (i) expiratory flow limitation (EFL) in health and (ii) changes in bronchial caliber in asthmatics. Using the slope-ratio (SR) index, we quantified MEFV curve shape in 84 healthy subjects and 8 matched asthmatics. Healthy subjects performed a maximal exercise test to assess EFL. Those with EFL during had a greater SR (1.15 ± 0.20 vs. 0.85 ± 0.20, p<0.05) yet, there was no association between maximal oxygen consumption and SR (r=0.14, p>0.05). Asthmatics average SR was greater than the healthy subjects (1.35 ± 0.03 vs. 0.90 ± 0.11, p<0.05), but there were no differences when bronchial caliber was manipulated. In conclusion, a greater SR is related to EFL and this metric could aid in discriminating between groups known to differ in the absolute size of MEFV curves.


Assuntos
Asma/fisiopatologia , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Adulto , Fármacos Cardiovasculares/administração & dosagem , Exercício Físico/fisiologia , Teste de Esforço , Feminino , Hélio/administração & dosagem , Humanos , Masculino , Oxigênio/administração & dosagem , Estudos Retrospectivos , Espirometria
5.
Neumol. pediátr. (En línea) ; 10(3): 134-136, jul. 2015. ilus
Artigo em Espanhol | LILACS | ID: lil-774014

RESUMO

Spirometry measures the forced expiratory volumes and flows. In patients with neuromuscular disease, these are altered since there is some respiratory muscle involvement. The usefulness of this test is based on the interpretation of the shape of the flow / volume loop and values of spirometric variables. In patients with neuromuscular disease, Forced Vital Capacity is the most used especially for its prognosis value.


La espirometría mide volúmenes y flujos espiratorios forzados. En los pacientes con enfermedad neuromuscular (ENM) estos se ven alterados debido al compromiso muscular respiratorio. La utilidad de este examen se basa en la interpretación de la forma de la curva flujo/volumen y los valores de las variables espirométricas. En los pacientes con ENM la Capacidad Vital Forzada es la más utilizada ya que otorga valor pronóstico.


Assuntos
Humanos , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Doenças Neuromusculares/fisiopatologia , Fluxo Expiratório Máximo/fisiologia , Músculos Respiratórios/fisiopatologia , Espirometria , Capacidade Vital
6.
Pediatr Pulmonol ; 50(10): 1017-24, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25367592

RESUMO

BACKGROUND: The concavity of the descending limb of the maximum expiratory flow-volume loop (MEFVL) is the earliest change associated with airflow obstruction in small airways (ATS/ERS Task Force). The shape of the MEFVL changes with age but there are no reference values for shape indices for preschool and school children. OBJECTIVES: To define pediatric reference values for spirometric data and 3 shape indices of MEFVL: 2 geometric indices: the ß angle i.e., the angle between the first ½ part and the 2nd part of the MEFVL and the forced expiratory flow after 50% of the forced vital capacity (FVC) has been exhaled/peak expiratory flow (FEF50 /PEF) ratio; and a ratio that describes relative growth between airway and lung parenchyma, the forced expiratory flow between 25 and 75% of FVC/FVC ratio (FEF25-75 /FVC ratio). METHODS: Data were obtained from 446 Caucasian children (2.5 to 15-year-old). The lambda, mu, sigma method was applied. RESULTS: References for spirometric parameters and 3 shape indices. The geometric indices decreased with age from 3 years of age (mean ß angle was 215° and FEF50 /PEF ratio was 0.82) until 8 years of age (mean ß angle was 191° and FEF50 /PEF ratio was 0.60) and then remained constant. The FEF25-75 /FVC ratio also decreased with age. Sex was a significant determinant for FEF25-75 /FVC ratio predicted values. CONCLUSIONS: This study provides standard reference equations for indices of mid-expiratory flows in children and we suggest using the FEF50 /PEF index.


Assuntos
Volume Expiratório Forçado/fisiologia , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Espirometria , Capacidade Vital/fisiologia , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Valores de Referência
7.
Neumol. pediátr. (En línea) ; 9(1): 31-33, 2014. graf, tab
Artigo em Espanhol | LILACS | ID: lil-773783

RESUMO

We describe physiological basis to explain flow/volume curve obtained by forced spirometry. The main factors involved are alveolar and intraluminal airway pressure and transthoracic pressure, whose interrelationship determines dynamic airway compression. Lung and thoracic elastic recoil pressure and lung volumes also participate.


Se describen las bases fisiológicas de la curva flujo/volumen obtenida mediante espirometría forzada. Los principales factores involucrados son la presión alveolar y de la vía aérea y la presión transtorácica, cuyo balance determina la compresión dinámica de la vía aérea. Además intervienen la presión de retracción elástica pulmonar y de la caja torácica y los volúmenes pulmonares.


Assuntos
Humanos , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Espirometria
8.
Pediatr Pulmonol ; 47(9): 884-94, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22328418

RESUMO

BACKGROUND: The earliest change associated with airflow obstruction in small airways is reflected in a concave shape on the maximum expiratory flow-volume loop (MEFVL). The shape of the MEFL changes with age but reference values for curvilinearity indices (CI) for preschool children have not been published. We aimed to describe the normal curvilinearity of healthy preschool MEFVL by CI (the ß angle and the ratio of maximum expiratory flow when 50% of forced vital capacity remains to be expired/peak expiratory flow (MEF(50%) /PEF)) and to test their capacity in detecting concavity in preschool children with wheezing disorders. METHODS: Spirometric data were obtained from 132 healthy preschool children and 171 3-to-5-year-old preschool children with wheezing disorders and reference values for CI calculated. RESULTS: Mean (SD) ß angle of healthy children was 203° (16°) and mean MEF(50%) /PEF of healthy children was 0.71 (0.12) indicating convexity of MEFVL, both decreased with increasing age (P = 10(-4) ). Children with wheezing disorders had lower z-score values of CI (P ≤ 10(-6) ) indicating more concave MEFVL. Among the two CI, MEF(50%) /PEF allowed for the best discrimination between healthy children and children with wheezing disorders (Wilks' lambda = 0.898, P = 10(-7) ). CONCLUSION: These CI can detect and quantify the concavity of the descending limb of the MEFVL in preschool children with wheezing disorders, MEF(50%) /PEF having the highest sensitivity in detecting the concavity.


Assuntos
Asma/fisiopatologia , Bronquíolos , Respiração , Bronquíolos/fisiologia , Bronquíolos/fisiopatologia , Estudos de Casos e Controles , Pré-Escolar , Feminino , Volume Expiratório Forçado , Humanos , Masculino , Fluxo Expiratório Máximo/fisiologia , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Pico do Fluxo Expiratório , Valores de Referência , Sons Respiratórios/fisiopatologia , Espirometria , Capacidade Vital/fisiologia
9.
Eur J Appl Physiol ; 112(6): 2001-12, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21947409

RESUMO

Weighted backpacks are used extensively in recreational and occupational settings, yet their effects on lung mechanics during acute exercise is poorly understood. The purpose of this study was to determine the effects of different backpack weights on lung mechanics and breathing patterns during treadmill walking. Subjects (n = 7, age = 28 ± 6 years), completed two 2.5-min exercise stages for each backpack condition [no backpack (NP), an un-weighted backpack (NW) or a backpack weighing 15, 25 or 35 kg]. A maximal expiratory flow volume curve was generated for each backpack condition and an oesophageal balloon catheter was used to estimate pleural pressure. The 15, 25 and 35 kg backpacks caused a 3, 5 and 8% (P < 0.05) reduction in forced vital capacity compared with the NP condition, respectively. For the same exercise stage, the power of breathing (POB) requirement was higher in the 35 kg backpack compared to NP (32 ± 4.3 vs. 88 ± 9.0 J min(-1), P < 0.05; respectively). Independent of changes in minute ventilation, end-expiratory lung volume decreased as backpack weight increased. As backpack weight increased, there was a concomitant decline in calculated maximal ventilation, a rise in minute ventilation, and a resultant greater utilization of maximal available ventilation. In conclusion, wearing a weighted backpack during an acute bout of exercise altered operational lung volumes; however, adaptive changes in breathing mechanics may have minimized changes in the required POB such that at an iso-ventilation, wearing a backpack weighing up to 35 kg does not increase the POB requirement.


Assuntos
Exercício Físico/fisiologia , Pulmão/fisiologia , Mecânica Respiratória/fisiologia , Caminhada/fisiologia , Adulto , Teste de Esforço/métodos , Volume Expiratório Forçado/fisiologia , Humanos , Medidas de Volume Pulmonar/métodos , Masculino , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Pico do Fluxo Expiratório/fisiologia , Treinamento Resistido/métodos , Ventilação/métodos , Capacidade Vital/fisiologia , Suporte de Carga , Adulto Jovem
10.
Sleep Breath ; 15(2): 157-62, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-20669051

RESUMO

PURPOSE: Flow-volume curves have been shown to relate to upper airway physiology during sleep and may be useful for predicting the response to treatment of obstructive sleep apnea (OSA) with mandibular advancement splints (MAS). The aim of this study was to prospectively assess the potential clinical utility of a previously derived prediction method using flow-volume curves performed during wakefulness. METHODS: Patients with newly diagnosed OSA interested in undertaking treatment with a custom-made MAS were approached to participate in the study. Response to treatment was defined by a 50% or greater reduction in the apnea-hypopnea index. Flow-volume curves were performed in the erect position prior to construction of the MAS. RESULTS: Flow-volume curves were performed in 35 patients. Of these, 25 patients were responders, and 10 patients were non-responders. A combined cut-off of an inspiratory flow rate at 50% of vital capacity (MIF50) less than 6.0 L/s and a ratio of the expiratory flow rate at 50% of vital capacity to MIF50 of greater than 0.7 correctly classified 48.6% of the patients. It had a sensitivity of 36.0%, specificity of 80.0%, positive predictive value of 81.8%, and negative predictive value of 33.3%. CONCLUSIONS: These results suggest that the previously derived prediction model, using flow-volume curves performed during wakefulness, was not sufficient to reliably predict the response to treatment of OSA with MAS. A combination of a functional assessment using flow-volume curves and a structural evaluation of the upper airway with imaging modalities may result in a prediction model with better performance characteristics.


Assuntos
Avanço Mandibular/instrumentação , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Placas Oclusais , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
11.
Comput Methods Programs Biomed ; 89(2): 123-31, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17459515

RESUMO

Flow limitation in the airways is a fundamental process constituting the maximal expiratory flow-volume curve. Its location is referred to as the choke point. In this work, expressions enabling the calculation of critical flows in the case of wave-speed, turbulent or viscous limitation were derived. Then a computational model for the forced expiration from the heterogeneous lung was used to analyse the regime and degree of flow limitation as well as movement and arrangement of the choke points. The conclusion is that flow limitation begins at similar time in every branch of the bronchial tree developing a parallel arrangement of the choke points. A serial configuration of flow-limiting sites is possible for short time periods in the case of increased airway heterogeneity. The most probable locations of choke points are the regions of airway junctions. The wave-speed mechanism is responsible for flow choking over most of vital capacity and viscous dissipation of pressure for the last part of the test. Turbulent dissipation, however, may play a significant role as a supporting factor in transition between wave-speed and viscous flow limitation.


Assuntos
Algoritmos , Pulmão/fisiologia , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Humanos , Polônia , Espirometria/estatística & dados numéricos
12.
Respir Care ; 52(12): 1744-52, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18028566

RESUMO

BACKGROUND: Spirometry, and in particular forced expiratory volume in the first second (FEV(1)), are standard tools for objective evaluation of asthma. However, FEV(1) does not correlate with symptom scores, and hence its value in the assessment of childhood asthma may be limited. Therefore, some clinicians subjectively assess the presence of curvature in the maximum expiratory flow-volume (MEFV) curves obtained from spirometry, where concave patterns are observable despite normal FEV(1) values. OBJECTIVE: To evaluate the usefulness of subjective and objective measures of the curvature in the descending phase of the MEFV curve for the assessment of asthma. METHODS: We obtained symptom scores and performed spirometry in 48 patients with asthma (21 females, mean +/- SD age 10.8 +/- 2.4 y). We measured FEV(1), the ratio of FEV(1) to forced vital capacity (FEV(1)/FVC), maximum expiratory flow at one quarter of the way, and at halfway, through the forced expiratory maneuver (MEF(25) and MEF(50), respectively), and maximum expiratory flow in the middle half of the forced expiratory maneuver (MEF(25-75)). Expiratory obstruction was ranked independently by 3 pediatric pulmonologists, by subjective assessment of the MEFV curve. In addition, the curvature of the descending limb of the MEFV curve was quantitatively estimated by introducing an "average curvature index." RESULTS: No significant correlations were found between FEV(1), MEF(50), MEF(25), and MEF(25-75,) respectively, and symptom score (r = -0.22, p = 0.14; r = -0.23, p = 0.11; r = -0.28, p = 0.057; r = -0.27, p = 0.06). A weak correlation was found for FEV(1)/FVC and symptom score (r = -0.33, p = 0.021). However, quantitatively determined average curvature index (ACI) correlated significantly better with measured symptom scores (r = 0.53, p < 0.001) and were in good agreement with the assessment of expiratory obstruction from subjective curvature assessment. CONCLUSIONS: Our general findings show that individual lung function variables do not correlate well with symptoms, whereas subjective curvature assessment is thought to be helpful. With the average curvature index we have illustrated a potential clinical usefulness of quantifying the curvatures of MEFV curves.


Assuntos
Asma/fisiopatologia , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Espirometria , Adolescente , Algoritmos , Criança , Feminino , Humanos , Masculino , Índice de Gravidade de Doença , Suíça
13.
Br J Surg ; 94(8): 966-9, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17440956

RESUMO

BACKGROUND: Cardiopulmonary exercise (CPX) testing measures how efficiently subjects meet increased metabolic demand. This study aimed to determine whether preoperative CPX testing predicted postoperative survival following elective abdominal aortic aneurysm (AAA) repair. METHODS: Some 130 patients had CPX testing before elective open AAA repair. Additional preoperative, operative and postoperative variables were recorded prospectively. Median follow-up was 35 months. The correlation of variables with survival was assessed by single and multiple regression analyses. RESULTS: CPX testing identified 30 of 130 patients who had been unfit before surgery. Two years after surgery the Kaplan-Meier survival estimate was 55 per cent for the 30 unfit patients, compared with 97 per cent for the 100 fit patients. The absolute difference in survival between these two groups at 2 years was 42 (95 per cent confidence interval 18 to 65) per cent (P < 0.001). CONCLUSION: Preoperative CPX testing, combined with simple co-morbidity scoring, identified patients unlikely to survive in the mid-term, even after successful AAA repair.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Complicações Pós-Operatórias/mortalidade , Análise de Variância , Aneurisma da Aorta Abdominal/mortalidade , Aneurisma da Aorta Abdominal/fisiopatologia , Dióxido de Carbono/metabolismo , Procedimentos Cirúrgicos Eletivos , Teste de Esforço , Humanos , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Consumo de Oxigênio , Aptidão Física , Complicações Pós-Operatórias/fisiopatologia , Cuidados Pré-Operatórios/métodos , Medição de Risco , Análise de Sobrevida
14.
High Alt Med Biol ; 6(3): 209-14, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16185138

RESUMO

Differences in static and dynamic volumes may exist between high altitude residents of Indian Himalayas and their South American counterparts, as well as with acclimatized lowlander sojourners. Maximum expiratory flow-volume loops were recorded in healthy native highlanders of Ladakh (NH, N = 75) and in healthy acclimatized lowlanders (AL, N = 32) at an altitude of 3450 m in the western Indian Himalayas. The forced vital capacity (FVC) and forced expiratory volume in the first second (FEV1), both corrected for a height of 168 cm, were significantly higher in NH [FVC: 5.02 (0.51) vs. 3.89 (0.45) L, p < 0.0001; FEV1: 4.27 (0.47) vs. 3.44 (0.37) L, p < 0.0001]. The flow rates at larger lung volumes (PEFR, FEF25, and FEF50) were similar in the two groups. The NH showed significantly higher flow rates at low lung volumes, that is, FEF75 and FEF75-85% [FEF75: 2.03 (0.69) vs. 1.70 (0.52) L/s, p = 0.0092; FEF75-85%: 1.42 (0.54) vs. 1.06 (0.35) L/s, p = 0.0001]. The exact mechanisms allowing the higher flow rates at low lung volumes remain to be elucidated, but it is possible that these findings may indicate an inherited adaptive response in the Ladakhi highlander.


Assuntos
Aclimatação/fisiologia , Adaptação Fisiológica , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Capacidade Pulmonar Total/fisiologia , Adulto , Doença da Altitude/diagnóstico , Feminino , Humanos , Índia , Masculino , Ventilação Pulmonar/fisiologia , Valores de Referência , Espirometria , Capacidade Vital/fisiologia
15.
Arch Pediatr ; 12(9): 1338-43, 2005 Sep.
Artigo em Francês | MEDLINE | ID: mdl-16023842

RESUMO

INTRODUCTION: To take in charge of an asthmatic child it is necessary to evaluate the lung function. METHODS: In this study, the Negative Expiratory Pressure (NEP) has been used for the first time in children with asthma. After lung spirometry by plethysmography, we have used the NEP to assess the prevalence of expiratory flow limitation (FL) during resting breath in 27 asthmatic children (mean age: 11 +/- 2,5 years) 3-4 days after a crisis in both sitting and supine positions. RESULTS: All the children presented an obstructive defect (FEV 1: 63 +/- 13% med) and a dynamic hyperinflation (FRC: 128 +/- 25% med). According to the NEP, 11 children presented an expiratory flow limitation (FL). Asthma was more severe in the FL than in non-FL children (GINA 2002 classification). Among the 11 FL children, 5 were FL in both sitting and supine position and 6 only in supine. Nine of the 27 children were FL with the conventional method. NEP seems a more accurate method to assess the clinical gravity of asthma than FEV 1. The reduction of FRC in the supine position probably explains the greater incidence of FL in supine position. CONCLUSION: Because of its easy execution, NEP seems to be well adapted for children. Links between FL detected by NEP and clinical signs of asthma has to be assessed by furthers studies including more patients.


Assuntos
Asma/diagnóstico , Adolescente , Asma/fisiopatologia , Criança , Expiração/fisiologia , Volume Expiratório Forçado/fisiologia , Capacidade Residual Funcional/fisiologia , Humanos , Capacidade Inspiratória/fisiologia , Pneumopatias Obstrutivas/fisiopatologia , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Pletismografia , Postura , Estudos Prospectivos , Ventilação Pulmonar/fisiologia , Volume Residual/fisiologia , Espirometria , Estado Asmático/fisiopatologia , Decúbito Dorsal , Capacidade Pulmonar Total/fisiologia , Capacidade Vital/fisiologia
16.
Pediatr Pulmonol ; 37(4): 318-23, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15022128

RESUMO

We compared three methods of reporting maximal expiratory flow (V'maxFRC) measured in partial expiratory flow-volume curves (PEFVCs) at the point of functional residual capacity (FRC). PEFVCs were obtained with the rapid thoracoabdominal compression technique (RTC) on a total of 446 occasions in 281 HIV-negative, asymptomatic infants (4.8-28.1 months old). Three different expressions of V'maxFRC were recorded: 1) the highest measured flow (maxV'FRC), 2) the mean of the three highest flows (mean3V'FRC), and 3) the flow at FRC in a composite curve (compV'FRC) consisting of PEFVCs, obtained at different jacket pressures and superimposed at their distal limb. The numerical value of maxV'FRC was 7.4% (+/-5.6%) higher than the mean3V'FRC, and 11.9% (+/-17.7%) higher than the compV'FRC; the mean3V'FRC was 5% (+/-18.3%) higher than the compV'FRC. Bland-Altman analysis was used to evaluate the agreement between the three indices. The mean difference and 95% limits of agreement were: maxV'FRC -mean3V'FRC, 14 +/- 18 ml/sec; maxV'FRC - compV'(FRC), 23 +/- 58 ml/sec; and mean3V'(FRC) - compV'(FRC), 10 +/- 52 ml/sec. The differences between the slopes of the three indices (regressed against height) were statistically significant, although clinically unimportant. We conclude that despite their high correlation, the mean3V'FRC and maxV'FRC should not be used interchangeably, and that the composite analysis, although useful, does not improve the reproducibility of V'maxFRC, and thus it cannot be recommended for routine use in its current form.


Assuntos
Fluxo Expiratório Máximo/fisiologia , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Pré-Escolar , Bases de Dados como Assunto , Feminino , Capacidade Residual Funcional/fisiologia , Humanos , Lactente , Masculino , Estudos Prospectivos , Valores de Referência , Análise de Regressão
17.
Indian J Physiol Pharmacol ; 46(1): 78-84, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-12024961

RESUMO

Maximal Expiratory Flow Volume (MEFV) curves were recorded with a computerized Spirometer (Med Spiror). Forced Vital Capacity (FVC), Forced Expiratory Volumes (FEV), mean and maximal flow rates were obtained in 25 quarry workers who were free from respiratory disorders and 20 healthy control subjects. All the functional values are lower in quarry workers than in the control subject, the largest reduction in quarry workers with a work duration of over 15 years, especially for FEF75. The effects are probably due to smoking rather than dust exposure.


Assuntos
Pulmão/efeitos dos fármacos , Mineração , Exposição Ocupacional/efeitos adversos , Dióxido de Silício/efeitos adversos , Adolescente , Adulto , Criança , Humanos , Pulmão/fisiologia , Masculino , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Mineração/estatística & dados numéricos , Exposição Ocupacional/estatística & dados numéricos , Fumar/efeitos adversos , Fumar/epidemiologia
18.
Indian J Med Sci ; 56(12): 607-12, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14514244

RESUMO

Flow volume loop and its various indices can be used to diagnose UAO. Change in posture from sitting to horizontal position per se causes a decrease in effort dependent inspiratory and expiratory flow rates but no significant change in upper airway obstruction indices. Thus, measurement of FVL in supine posture may be used to detect UAO as it may be missed if spirometry is performed in sitting posture.


Assuntos
Postura/fisiologia , Mecânica Respiratória/fisiologia , Adulto , Peso Corporal/fisiologia , Volume Expiratório Forçado/fisiologia , Humanos , Masculino , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia
19.
Respir Med ; 95(11): 898-903, 2001 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-11716204

RESUMO

Duchenne's muscular dystrophy (DMD), characterized by gradually developing muscular weakness, leads to respiratory symptoms and reduced lung function. We aimed to assess lung function in 25 patients with DMD in relationship to age and muscular function. The 25 boys, mean age 13 years, comprized patients in southern Norway with DMD, taking part in an epidemiological follow-up study. None had chronic respiratory disease. Lung function was measured by maximum expiratory flow-volume loops and whole body plethysmography, and repeated after 1 year (n= 14). Lung function was reduced compared to predicted values for healthy children. Forced expiratory volume in 1 sec (FEV1)% predicted and forced vital capacity (FVC)% predicted correlated (significantly) inversely to age. FEV1 and FVC decreased annually 5.61 and 4.2% of predicted, respectively. Absolute values of FVC (litres) and FEV1 (1 sec(-1)) increased until mean age 14 years, decreasing thereafter. Values in % predicted decreased steadily throughout the age range (6-19 years). Lung function correlated closely to upper limb muscle function.


Assuntos
Pulmão/fisiopatologia , Distrofia Muscular de Duchenne/fisiopatologia , Músculos Respiratórios/fisiopatologia , Adolescente , Adulto , Fatores Etários , Análise de Variância , Criança , Volume Expiratório Forçado/fisiologia , Humanos , Masculino , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Fluxo Máximo Médio Expiratório/fisiologia , Pico do Fluxo Expiratório/fisiologia , Pletismografia Total/métodos , Análise de Regressão , Volume Residual/fisiologia , Estatísticas não Paramétricas , Capacidade Pulmonar Total/fisiologia , Capacidade Vital/fisiologia
20.
Respir Med ; 95(7): 618-26, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11453321

RESUMO

The product of walking distance and body weight (D x W) mimics the work of walking. We hypothesized the superiority of D x W to walking distance (D) alone in any correlation with lung function, anaerobic threshold (AT) and maximal oxygen uptake (VO2max). We further hypothesized that the D x W product for a 6-min walk test (6 MWT) would correlate with the AT and VO2max because all three are markers of exercise ability. Thirty-three male chronic obstructive pulmonary disease (COPD) patients with mean forced expiratory volume in 1 sec (FEV1) of 1.2+/-0.4 l (range 0.58-1.86 l) were enrolled. Six patients were excluded due to inability to achieve a maximal test. Lung function and self-assessed every-day activities using a oxygen-cost diagram were evaluated before entry of the study. A maximal effort ramp-pattern cardiopulmonary exercise test (CPET) and a 6 MWT were conducted in random order. Borg score, heart rate, and O2 saturation with pulse oximetry (SpO2) were measured during both exercise tests. VO2 AT and minute ventilation were also measured during the CPET. Correlations were sought between the distance covered in the 6 MWT, and the D x W product with AT, VO2max and other variables. The average D and D x W were 456 m and 27.5 kg km(-1), respectively. D x W was superior to D alone when correlated with the VO2max and AT determined from the CPET, while modestly correlated with the change (delta) in Borg score and delta SpO2 in the 6 MWT and self-assessed every-day activities. Distance x weight product was correlated with the AT and VO2max. In addition, D x W was better correlated with diffusing capacity for carbon monoxide and vital capacity than D alone. We conclude that D x W mimics the work of walking better than D and is suggested as a parameter for evaluation of patients' fitness if gas exchange measurements are not available.


Assuntos
Limiar Anaeróbio/fisiologia , Peso Corporal/fisiologia , Pneumopatias Obstrutivas/fisiopatologia , Consumo de Oxigênio/fisiologia , Caminhada/fisiologia , Atividades Cotidianas , Idoso , Teste de Esforço/métodos , Volume Expiratório Forçado/fisiologia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Curvas de Fluxo-Volume Expiratório Máximo/fisiologia , Pessoa de Meia-Idade , Oximetria , Valor Preditivo dos Testes , Volume Residual/fisiologia , Capacidade Pulmonar Total/fisiologia , Capacidade Vital/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA